Sensitivity analysis of a High Gain DC/DC boost converter including parasitic parameters

Authors

  • F. Alonge Author
  • M. Pucci Author
  • R. Rabbeni Author
  • G. Vitale Author

DOI:

https://doi.org/10.24084/repqj12.415

Keywords:

DC/DC boost converter, sensitivity analysis

Abstract

A high gain DC/DC boost converter is presented. This circuit is analysed with reference to the sensitivity analysis of the static gain transfer function including parasitic parameters. Results demonstrate that a low parasitic resistance of the input inductor gives a quasi-ideal behaviour in terms of efficiency and boosting but, on the other hand, it implies high variation of the static gain versus the duty cycle at its high. This kind of analysis is particular meaningful, since it has been demonstrated that the sensitivity of the HG (High Gain) boost DC-DC converter to the parasitic resistance of the input inductance is higher for lower values of the parasitic resistance.

Author Biographies

  • F. Alonge

    Università degli Studi di Palermo – Facoltà di Ingegneria  
    Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici – DEIM 
    Viale delle Scienze Palermo, Italy. 

  • M. Pucci

     ISSIA-CNR (Insitute of Intelligent Systems for the Automation), Palermo, Italy 

  • R. Rabbeni

    Università degli Studi di Palermo – Facoltà di Ingegneria  
    Dipartimento di Energia, Ingegneria dell’Informazione e Modelli Matematici – DEIM 
    Viale delle Scienze Palermo, Italy.

  • G. Vitale

     ISSIA-CNR (Insitute of Intelligent Systems for the Automation), Palermo, Italy 