Transient Current Response Modeling and Voltage Analysis of Three-Phase PWM Inverter Systems Considering Parasitic Parameters and Passive EMI Filter Effects

Authors

  • YunHo Pak Faculty of Electrical Engineering, Kim Chaek University of Technology, Pyongyang, Democratic People’s Republic of Korea Author
  • JuSong Kim Faculty of Electrical Engineering, Kim Chaek University of Technology, Pyongyang, Democratic People’s Republic of Korea Author
  • YongSim Ro Faculty of Electrical Engineering, Kim Chaek University of Technology, Pyongyang, Democratic People’s Republic of Korea Author
  • Jinhyok Ri Faculty of Electrical Engineering, Kim Chaek University of Technology, Pyongyang, Democratic People’s Republic of Korea Author

DOI:

https://doi.org/10.64229/a2rpv209

Keywords:

Three-phase PWM inverter, Transient current response, Voltage impulse, Passive EMI filter, Parasitic capacitance, State-space model, Leakage current, Motor drive

Abstract

High-frequency switching in pulse-width-modulated (PWM) inverter systems for renewable energy applications produces steep voltage impulses and current transients that excite parasitic current paths, increase common-mode and differential-mode electromagnetic interference (EMI), and degrade power quality in inverter-fed motor drives. This paper develops a transient current-response model for a three-phase PWM inverter by explicitly considering the load impedance, parasitic capacitance associated with the inverter heat sink and motor structure, and the dynamics of a passive inductor-capacitor (LC) output filter For the load-only and parasitic-capacitance cases, analytical current responses are derived in the Laplace domain for a trapezoidal switching-voltage impulse whose rising, on-state, falling, and post-pulse intervals are treated separately. When the LC filter is included, a state-space formulation is adopted and solved numerically by a fourth-order Runge-Kutta procedure with a time step of 0.1 μs. The model is evaluated for a 380-V, 139-A, 60-Hz, 75-kW induction motor supplied by a 130-kVA inverter with a 2.4-kHz carrier frequency. The calculated heat-sink-related parasitic capacitance is 394.93 pF. Comparative MATLAB simulations show that filter parameters strongly influence inverter output current, filter-capacitor voltage, load-current distortion, and overall power quality. The case  L=2 mH and  C=50 μF provides the smoothest waveforms and the lowest simulated load-current total harmonic distortion (THD = 2.3%) among the investigated configurations, whereas an inadequately selected filter can increase high-frequency current stress and worsen power quality. The proposed framework provides a simulation-based screening tool for passive filter parameters. Experimental validation, including filter-capacitor voltage, load-current, and full electromagnetic compatibility (EMC) measurements, remains necessary and is identified as future work.