Transient Current Response Modeling and Voltage Analysis of Three-Phase PWM Inverter Systems Considering Parasitic Parameters and Passive EMI Filter Effects
DOI:
https://doi.org/10.64229/a2rpv209Keywords:
Three-phase PWM inverter, Transient current response, Voltage impulse, Passive EMI filter, Parasitic capacitance, State-space model, Leakage current, Motor driveAbstract
High-frequency switching in pulse-width-modulated (PWM) inverter systems for renewable energy applications produces steep voltage impulses and current transients that excite parasitic current paths, increase common-mode and differential-mode electromagnetic interference (EMI), and degrade power quality in inverter-fed motor drives. This paper develops a transient current-response model for a three-phase PWM inverter by explicitly considering the load impedance, parasitic capacitance associated with the inverter heat sink and motor structure, and the dynamics of a passive inductor-capacitor (LC) output filter For the load-only and parasitic-capacitance cases, analytical current responses are derived in the Laplace domain for a trapezoidal switching-voltage impulse whose rising, on-state, falling, and post-pulse intervals are treated separately. When the LC filter is included, a state-space formulation is adopted and solved numerically by a fourth-order Runge-Kutta procedure with a time step of 0.1 μs. The model is evaluated for a 380-V, 139-A, 60-Hz, 75-kW induction motor supplied by a 130-kVA inverter with a 2.4-kHz carrier frequency. The calculated heat-sink-related parasitic capacitance is 394.93 pF. Comparative MATLAB simulations show that filter parameters strongly influence inverter output current, filter-capacitor voltage, load-current distortion, and overall power quality. The case L=2 mH and C=50 μF provides the smoothest waveforms and the lowest simulated load-current total harmonic distortion (THD = 2.3%) among the investigated configurations, whereas an inadequately selected filter can increase high-frequency current stress and worsen power quality. The proposed framework provides a simulation-based screening tool for passive filter parameters. Experimental validation, including filter-capacitor voltage, load-current, and full electromagnetic compatibility (EMC) measurements, remains necessary and is identified as future work.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 YunHo Pak, JuSong Kim, YongSim Ro, Jinhyok Ri (Author)

This work is licensed under a Creative Commons Attribution 4.0 International License.