Detection of inter-coil short circuits in coils of salient pole synchronous generator field winding on the basis of analysis of magnetic field in the machine
DOI:
https://doi.org/10.24084/repqj08.293Abstract
This paper deals with detection of inter-coil short
circuits in coils of the salient pole synchronous generator field
winding, on the basis of the analysis of the magnetic field in the
machine. Applying FEM to the generator model, magnetic field
wave forms in the machine were calculated, on the points of
interests, under both, faultless and faulty conditions. When
results were compared, changes in wave forms caused by the
analyzed fault were identified. Using the model, flux density
and magnetic flux were calculated on the points accessible for
measuring with Hall’s sensors and measuring coils in the actual
machine. The aim of this paper is a contribution in the field of
faults and failures identification in rotating machines, that is,
improvement of monitoring systems aimed for rotating machine
condition monitoring.